Delete temp-humid-read-loop.py

This commit is contained in:
Jonny Ervine
2015-06-17 12:35:47 +08:00
parent 02f78682db
commit 0e045fc8b7
-139
View File
@@ -1,139 +0,0 @@
#!/usr/bin/env python
# -*- coding:utf-8 -*-
import sys
import dhtreader
import updateMysql
import ConfigParser
import time
from threading import Timer,Thread,Event
import logging
from datetime import timedelta
from datetime import datetime
oldtemp = "NULL"
oldhumid = "NULL"
def exec_every_n_seconds(n,f,*args):
first_called=datetime.now()
print args
f(*args)
num_calls=1
drift=timedelta()
time_period=timedelta(seconds=n)
while 1:
time.sleep(n-drift.microseconds/1000000.0)
current_time = datetime.now()
f(*args)
num_calls += 1
difference = current_time - first_called
drift = difference - time_period* num_calls
print "drift=",drift
def sensorRead(hwtype, pin, retries, timeout, maxtemp, mintemp, maxhumid, minhumid):
global oldtemp
global oldhumid
for num in range(retries):
try:
t, h = dhtreader.read(dev_type, dhtpin)
except:
if ((num + 1) < retries):
print('Exception detected! We will retry. Loop number: %d', num)
logging.warning('Exception detected! We will retry. Loop number: %d', num)
time.sleep(timeout)
else:
print('Exception detected - we are out of retries. Skipping the measurement in this cycle.')
logging.error('Exception detected - we are out of retries. Skipping the measurement in this cycle.')
else:
if t and h:
print(t, h)
if (oldtemp != "NULL") and ((t - oldtemp < tempdiff) or (oldtemp - t < tempdiff)) and ((h - oldhumid < humiddiff) or (oldhumid - h < humiddif)):
print('Current temperature close enough to previous temperature and previous temperature is not NULL, it is:')
logging.debug('Current temperature close enough to previous temperature and previous temperature is not NULL, it is: %s', oldtemp)
print oldtemp
print('Current humidity close enough to previous humidity and previous humidity is not NULL, it is:')
logging.debug('Current humidity close enough to previous humidity and previous humidity is not NULL, it is: %s', oldhumid)
print oldhumid
if (t < maxtemp) and (t > mintemp) and (h < maxhumid) and (h > minhumid):
print('Temperature is less than {0} and greater than {1}, humidity is less than {2} and greater than {3}'.format(maxtemp,mintemp,maxhumid,minhumid))
logging.debug('Temperature is less than {0} and greater than {1}, humidity is less than {2} and greater than {3}'.format(maxtemp,mintemp,maxhumid,minhumid))
updateMysql.main(t, h, host, db, username, password)
oldtemp=t
oldhumid=h
break
else:
print('Temperature {0} or humidity {1} is outside of allowable values - error! Check your configuration.'.format(t, h))
logging.error('Temperature {0} or humidity {1} is outside of allowable values - error! Check your configuration.'.format(t, h))
else:
print("Failed to read from sensor, maybe try again?")
logging.warning('Failed to read from sensor, maybe try again?')
return 0
DHT11 = 11
DHT22 = 22
AM2302 = 22
config = ConfigParser.ConfigParser()
config.read('temphumid.conf')
hwtype=config.get('hardware', 'DHT')
pin=config.get('hardware', 'PIN')
retries=int(config.get('software', 'retries'))
timeout=int(config.get('software', 'timeout'))
interval=int(config.get('software', 'interval'))
maxtemp=int(config.get('software', 'maxtemp'))
mintemp=int(config.get('software', 'mintemp'))
tempdiff=int(config.get('software', 'tempdiff'))
maxhumid=int(config.get('software', 'maxhumid'))
minhumid=int(config.get('software', 'minhumid'))
humiddiff=int(config.get('software', 'humiddiff'))
logfile=(config.get('software', 'logfile'))
loglevel=(config.get('software', 'loglevel'))
host=(config.get('database', 'host'))
db=(config.get('database', 'db'))
username=(config.get('database', 'username'))
password=(config.get('database', 'password'))
if loglevel == "debug":
logging.basicConfig(filename = logfile, format='%(asctime)s %(levelname)s:%(message)s', datefmt='%Y-%m-%d %H:%M:%S', level=logging.DEBUG)
elif loglevel == "info":
logging.basicConfig(filename = logfile, format='%(asctime)s %(levelname)s:%(message)s', datefmt='%Y-%m-%d %H:%M:%S', level=logging.INFO)
elif loglevel == "warn":
logging.basicConfig(filename = logfile, format='%(asctime)s %(levelname)s:%(message)s', datefmt='%Y-%m-%d %H:%M:%S', level=logging.WARNING)
elif loglevel == "error":
logging.basicConfig(filename = logfile, format='%(asctime)s %(levelname)s:%(message)s', datefmt='%Y-%m-%d %H:%M:%S', level=logging.ERROR)
else:
logging.basicConfig(filename = logfile, format='%(asctime)s %(levelname)s:%(message)s', datefmt='%Y-%m-%d %H:%M:%S', level=logging.CRITICAL)
dhtreader.init()
dev_type = None
if hwtype == "11":
dev_type = DHT11
print('Configured to use DHT11 device')
logging.info('Configured to use DHT11 device')
elif hwtype == "22":
dev_type = DHT22
print('Configured to use DHT22 device')
logging.info('Configured to use DHT22 device')
elif hwtype == "2302":
dev_type = AM2302
print('Configured to use AM 2302 device')
logging.info('Configured to use AM2303 device')
else:
print('Invalid hardware type, only DHT11, DHT22 and AM 2302 are supported for now.!')
logging.warn('Invalid hardware type, only DHT11, DHT22 and AM 2302 are supported for now.!')
sys.exit(3)
dhtpin = int(pin)
if dhtpin <= 0:
print("Invalid GPIO pin#, correct your configuration file")
logging.warn("Invalid GPIO pin#, correct your configuration file")
sys.exit(3)
print("using pin #{0}".format(dhtpin))
logging.info("using pin #{0}".format(dhtpin))
print('About to enter infinte loop ...')
logging.info("About to enter infinite loop")
exec_every_n_seconds(60,sensorRead,hwtype,pin,retries,timeout,maxtemp,mintemp,maxhumid,minhumid)