Fix sensor validation, MySQL retries, and chart query bugs.

Reject implausible readings, close DB connections on retry, and return chart data in chronological order.

Co-authored-by: Cursor <cursoragent@cursor.com>
This commit is contained in:
2026-08-14 19:40:49 +08:00
co-authored by Cursor
parent c6616bd855
commit 6f12d2c459
8 changed files with 387 additions and 286 deletions
+67 -92
View File
@@ -1,111 +1,86 @@
#!/usr/bin/env python
# -*- coding:utf-8 -*-
import sys
import logging
import time
import dhtreader
import updateMysql
import readMysql
import ConfigParser
import logging
import time
from time import strftime
from datetime import datetime
from datetime import timedelta
import thmonitor_common as common
oldtemp = "NULL"
oldhumid = "NULL"
def sensorRead(hwtype, pin, retries, timeout, maxtemp, mintemp, tempdiff, maxhumid, minhumid, humiddiff):
global oldtemp
global oldhumid
oldtemp, oldhumid = readMysql.main(host, db, username, password, logging, sql_retries, sql_timeout)
logging.debug('We have returned the following previous temperature {0} and humidity {1} values.'.format(oldtemp, oldhumid))
for num in range(retries):
def sensor_read(cfg, dev_type, dhtpin):
"""Perform a single sensor read using the last DB values for validation."""
oldtemp, oldhumid = readMysql.main(
cfg['host'], cfg['db'], cfg['username'], cfg['password'],
logging, cfg['sql_retries'], cfg['sql_timeout'],
)
logging.debug(
'Previous temperature %s and humidity %s loaded from database.',
oldtemp, oldhumid,
)
limits = {
'maxtemp': cfg['maxtemp'],
'mintemp': cfg['mintemp'],
'tempdiff': cfg['tempdiff'],
'maxhumid': cfg['maxhumid'],
'minhumid': cfg['minhumid'],
'humiddiff': cfg['humiddiff'],
}
for num in range(cfg['retries']):
try:
t, h = dhtreader.read(dev_type, dhtpin)
except:
if ((num + 1) < retries):
logging.warning('Exception detected! We will retry. Loop number: %d', num)
time.sleep(timeout)
except Exception:
if num + 1 < cfg['retries']:
logging.warning(
'Exception during sensor read; retry %d/%d',
num + 1, cfg['retries'],
)
time.sleep(cfg['timeout'])
else:
logging.error('Exception detected - we are out of retries. Skipping the measurement in this cycle.')
else:
if t and h:
logging.debug('The temperature and humidity have been read as {0} and {1}'.format(t, h))
if (oldtemp != "NULL") and ((t - oldtemp < tempdiff) or (oldtemp - t < tempdiff)) and ((h - oldhumid < humiddiff) or (oldhumid - h < humiddiff)):
logging.debug('Current temperature close enough to previous temperature and previous temperature is not NULL, it is: %s', oldtemp)
logging.debug('Current humidity close enough to previous humidity and previous humidity is not NULL, it is: %s', oldhumid)
if (t < maxtemp) and (t > mintemp) and (h < maxhumid) and (h > minhumid):
logging.debug('Temperature is less than {0} and greater than {1}, humidity is less than {2} and greater than {3}'.format(maxtemp,mintemp,maxhumid,minhumid))
updateMysql.main(t, h, host, db, username, password, logging, sql_retries, sql_timeout)
oldtemp=t
oldhumid=h
break
else:
logging.error('Temperature {0} or humidity {1} is outside of allowable values - error! Check your configuration.'.format(t, h))
else:
logging.warning('Failed to read from sensor, maybe try again?')
return 0
logging.error(
'Sensor read failed after %d attempts; giving up.',
cfg['retries'],
)
continue
DHT11 = 11
DHT22 = 22
AM2302 = 22
if not t or not h:
logging.warning('Sensor returned empty reading; retrying.')
if num + 1 < cfg['retries']:
time.sleep(cfg['timeout'])
continue
config = ConfigParser.ConfigParser()
config.read('/etc/thMonitor.conf')
hwtype=config.get('hardware', 'DHT')
pin=config.get('hardware', 'PIN')
retries=int(config.get('software', 'retries'))
timeout=int(config.get('software', 'timeout'))
interval=int(config.get('software', 'interval'))
maxtemp=int(config.get('software', 'maxtemp'))
mintemp=int(config.get('software', 'mintemp'))
tempdiff=int(config.get('software', 'tempdiff'))
maxhumid=int(config.get('software', 'maxhumid'))
minhumid=int(config.get('software', 'minhumid'))
humiddiff=int(config.get('software', 'humiddiff'))
logfile=(config.get('software', 'logfile'))
loglevel=(config.get('software', 'loglevel'))
host=(config.get('database', 'host'))
db=(config.get('database', 'db'))
username=(config.get('database', 'username'))
password=(config.get('database', 'password'))
sql_retries=int((config.get('database', 'sql_retries')))
sql_timeout=(config.get('database', 'sql_timeout'))
logging.debug('Temperature and humidity read as %s and %s', t, h)
if common.reading_is_plausible(t, h, oldtemp, oldhumid, limits):
updateMysql.main(
t, h,
cfg['host'], cfg['db'], cfg['username'], cfg['password'],
logging, cfg['sql_retries'], cfg['sql_timeout'],
)
return 0
if num + 1 < cfg['retries']:
time.sleep(cfg['timeout'])
return 1
if loglevel == "debug":
logging.basicConfig(filename = logfile, format='%(asctime)s %(levelname)s:%(message)s', datefmt='%Y-%m-%d %H:%M:%S', level=logging.DEBUG)
elif loglevel == "info":
logging.basicConfig(filename = logfile, format='%(asctime)s %(levelname)s:%(message)s', datefmt='%Y-%m-%d %H:%M:%S', level=logging.INFO)
elif loglevel == "warn":
logging.basicConfig(filename = logfile, format='%(asctime)s %(levelname)s:%(message)s', datefmt='%Y-%m-%d %H:%M:%S', level=logging.WARNING)
elif loglevel == "error":
logging.basicConfig(filename = logfile, format='%(asctime)s %(levelname)s:%(message)s', datefmt='%Y-%m-%d %H:%M:%S', level=logging.ERROR)
else:
logging.basicConfig(filename = logfile, format='%(asctime)s %(levelname)s:%(message)s', datefmt='%Y-%m-%d %H:%M:%S', level=logging.CRITICAL)
def main():
cfg = common.load_config()
common.setup_logging(cfg['logfile'], cfg['loglevel'])
dhtreader.init()
dhtreader.init()
dev_type = common.resolve_dht_type(cfg['hwtype'])
dhtpin = common.validate_pin(cfg['pin'])
dev_type = None
if hwtype == "11":
dev_type = DHT11
logging.info('Configured to use DHT11 device')
elif hwtype == "22":
dev_type = DHT22
logging.info('Configured to use DHT22 device')
elif hwtype == "2302":
dev_type = AM2302
logging.info('Configured to use AM2303 device')
else:
logging.warn('Invalid hardware type, only DHT11, DHT22 and AM 2302 are supported for now.!')
sys.exit(3)
logging.info(
'Single run temperature and humidity reading '
'[version: 1.1, Jonathan Ervine, 2015-06-17]'
)
return sensor_read(cfg, dev_type, dhtpin)
dhtpin = int(pin)
if dhtpin <= 0:
logging.warn("Invalid GPIO pin#, correct your configuration file")
sys.exit(3)
logging.info("using pin #{0}".format(dhtpin))
logging.info('Single run temperature and humidity reading. [version: 1.0, Jonathan Ervine, 2015-06-17]')
sensorRead(hwtype,pin,retries,timeout,maxtemp,mintemp,tempdiff,maxhumid,minhumid,humiddiff)
if __name__ == '__main__':
raise SystemExit(main())