Fix sensor validation, MySQL retries, and chart query bugs.

Reject implausible readings, close DB connections on retry, and return chart data in chronological order.

Co-authored-by: Cursor <cursoragent@cursor.com>
This commit is contained in:
2026-08-14 19:40:49 +08:00
co-authored by Cursor
parent c6616bd855
commit 6f12d2c459
8 changed files with 387 additions and 286 deletions
+3 -1
View File
@@ -1,4 +1,6 @@
## TO DO LIST
- Update the single run python script so that it reads the MySQL database for the previous values of temperature and humidity, as it doesn't loop and therefore doesn't maintain the previous readings.
- Consider migrating from the legacy Python 2 / dhtreader.so stack to a maintained
DHT library (e.g. Adafruit CircuitPython or lgpio-based driver) for current Pi OS releases.
- Externalize getData.php database credentials into a config file outside the web root.
+24 -19
View File
@@ -4,42 +4,47 @@ $username = "USERNAME";
$password = "PASSWORD";
$dbname = "Monitoring";
$rows = array();
$table = array();
$table['cols'] = array(
// Labels for your chart, these represent the column titles
array('label' => 'Date and Time', 'type' => 'number'),
array('label' => 'Temperature', 'type' => 'number'),
array('label' => 'Humidity', 'type' => 'number')
);
// Create connection
//$conn = new mysqli($servername, $username, $password, $dbname);
$conn = mysqli_connect($servername, $username, $password, $dbname);
// Check connection
if ($conn->connect_error) {
die("Connection failed: " . $conn->connect_error);
if (!$conn) {
header('HTTP/1.1 500 Internal Server Error');
header('Content-type: application/json');
echo json_encode(array('error' => 'Connection failed: ' . mysqli_connect_error()));
exit;
}
$sql = "SELECT ComputerTime, Temperature, Humidity from TempHumid ORDER BY id DESC LIMIT 360";
$sql = "SELECT ComputerTime, Temperature, Humidity FROM ("
. "SELECT ComputerTime, Temperature, Humidity FROM TempHumid "
. "ORDER BY id DESC LIMIT 360"
. ") AS recent ORDER BY ComputerTime ASC";
$result = mysqli_query($conn, $sql);
//if ($result->num_rows > 0) {
// output data of each row
$rows = array();
if ($result) {
while ($row = mysqli_fetch_array($result)) {
$temp = array();
// $datetime = date('d/m/Y H:i', $row[0]);
// $temp[] = array('v' => $datetime);
$temp[] = array('v' => $row[0]);
$temp[] = array('v' => $row[1]);
$temp[] = array('v' => $row[2]);
$temp[] = array('v' => (float)$row[0]);
$temp[] = array('v' => (float)$row[1]);
$temp[] = array('v' => (float)$row[2]);
$rows[] = array('c' => $temp);
}
//} else {
// echo "No current temperature - ERROR?";
//}
mysqli_free_result($result);
} else {
header('HTTP/1.1 500 Internal Server Error');
header('Content-type: application/json');
echo json_encode(array('error' => 'Query failed: ' . mysqli_error($conn)));
mysqli_close($conn);
exit;
}
$table['rows'] = $rows;
header('Content-type: application/json');
echo json_encode($table);
$conn->close();
mysqli_close($conn);
?>
+41 -22
View File
@@ -2,34 +2,53 @@
##
## Script to read the last temperature and humidity readings from a MySQL database
##
import sys
import time
import MySQLdb
NO_PREVIOUS = ('NULL', 'NULL')
def main(host, db, user, passwd, logging, sql_retries, sql_timeout):
logging.debug('Reading MySQL database next ...')
sql = (
'SELECT Temperature, Humidity FROM TempHumid '
'ORDER BY ComputerTime DESC LIMIT 1'
)
for attempt in range(sql_retries):
connection = None
try:
connection = MySQLdb.connect(host, user, passwd, db)
cursor = connection.cursor()
sql = """SELECT Temperature, Humidity FROM TempHumid ORDER BY ComputerTime DESC LIMIT 1"""
success = False
attempts = 0
while attempts < sql_retries and not success:
try:
cursor.execute(sql)
data = cursor.fetchall()
for row in data :
temp = row[0]
humid = row[1]
oldtemp = float(temp)
oldhumid = float(humid)
logging.debug('The MySQL database was successfully read.')
connection.commit()
row = cursor.fetchone()
cursor.close()
logging.debug('The previous temperature was: {0}C and the previous humidity was {1}%'.format(oldtemp, oldhumid))
success = True
except MySQLdb.Error, e:
logging.warn('The MySQL database could not be read and returned the following error %d: %s', (e.args[0], e.args[1]))
attempts += 1
if attempts == sql_retries:
logging.error('All configured attempts to read the MySQL database have failed. We are going to skip this attempt.')
time.sleep(sql_interval)
if row is None:
logging.info('No previous readings found in database.')
return NO_PREVIOUS
oldtemp = float(row[0])
oldhumid = float(row[1])
logging.debug(
'Previous temperature: %sC, previous humidity: %s%%',
oldtemp, oldhumid,
)
return oldtemp, oldhumid
except MySQLdb.Error as e:
logging.warn(
'MySQL read failed (attempt %d/%d): %d: %s',
attempt + 1, sql_retries, e.args[0], e.args[1],
)
if attempt + 1 >= sql_retries:
logging.error(
'All configured attempts to read the MySQL database have failed.'
)
return NO_PREVIOUS
time.sleep(sql_timeout)
finally:
if connection is not None:
connection.close()
return NO_PREVIOUS
+77 -118
View File
@@ -1,141 +1,100 @@
#/usr/bin/env python
#!/usr/bin/env python
# -*- coding:utf-8 -*-
import sys
import time
import logging
import dhtreader
import updateMysql
import ConfigParser
import time
from time import strftime
from threading import Timer,Thread,Event
import logging
from datetime import datetime
from datetime import timedelta
import thmonitor_common as common
oldtemp = "NULL"
oldhumid = "NULL"
oldtemp = 'NULL'
oldhumid = 'NULL'
def exec_every_n_seconds(n,f,*args):
waitInterval = timedelta(seconds=n)
logging.debug('We should read the sensor every {0} seconds'.format(waitInterval))
duration=f(*args)
offset = waitInterval - duration
logging.debug('Running the loop again in {0} seconds (printed as datetime)'.format(offset))
offset2 = offset.total_seconds()
logging.debug('Running the loop again in {0} seconds (printed as float)'.format(offset2))
while 1:
logging.debug('We are in the loop now ...')
initTime=time.time()
logging.debug('Start time is {0}'.format(initTime))
#time.sleep(offset2)
logging.debug('We are about to run the sensor read again')
duration=f(*args)
offset2 = (60.0 - (time.time() - initTime))
time.sleep(60.0 - ((time.time() - initTime) % 60.0))
logging.debug('Duration of sequence was: {0}'.format(duration))
offset = waitInterval - duration
logging.debug('Running the loop again in {0} seconds (printed as dateime)'.format(offset))
#offset2 = offset.total_seconds()
logging.debug('Running the loop again in {0} seconds (printed as float)'.format(offset2))
def sensorRead(hwtype, pin, retries, timeout, maxtemp, mintemp, tempdiff, maxhumid, minhumid, humiddiff):
global oldtemp
global oldhumid
startTime=datetime.now()
logging.debug('This round of results started at {0}'.format(startTime))
for num in range(retries):
def sensor_read(cfg, dev_type, dhtpin):
"""Read sensor, validate, and store a single measurement."""
global oldtemp, oldhumid
start = time.time()
limits = {
'maxtemp': cfg['maxtemp'],
'mintemp': cfg['mintemp'],
'tempdiff': cfg['tempdiff'],
'maxhumid': cfg['maxhumid'],
'minhumid': cfg['minhumid'],
'humiddiff': cfg['humiddiff'],
}
for num in range(cfg['retries']):
try:
t, h = dhtreader.read(dev_type, dhtpin)
except:
if ((num + 1) < retries):
logging.warning('Exception detected! We will retry. Loop number: %d', num)
time.sleep(timeout)
except Exception:
if num + 1 < cfg['retries']:
logging.warning(
'Exception during sensor read; retry %d/%d',
num + 1, cfg['retries'],
)
time.sleep(cfg['timeout'])
else:
logging.error('Exception detected - we are out of retries. Skipping the measurement in this cycle.')
else:
if t and h:
logging.debug('Temperature and humidity read as {0} and {1}'.format(t, h))
logging.debug('Temperature and Humidity differences allowed: {0} and {1}'.format(tempdiff, humiddiff))
if (oldtemp != "NULL") and ((t - oldtemp < tempdiff) or (oldtemp - t < tempdiff)) and ((h - oldhumid < humiddiff) or (oldhumid - h < humiddiff)):
logging.debug('Current temperature close enough to previous temperature and previous temperature is not NULL, it is: %s', oldtemp)
logging.debug('Current humidity close enough to previous humidity and previous humidity is not NULL, it is: %s', oldhumid)
if (t < maxtemp) and (t > mintemp) and (h < maxhumid) and (h > minhumid):
logging.debug('Temperature is less than {0} and greater than {1}, humidity is less than {2} and greater than {3}'.format(maxtemp,mintemp,maxhumid,minhumid))
updateMysql.main(t, h, host, db, username, password, logging, sql_retries, sql_timeout)
logging.error(
'Sensor read failed after %d attempts; skipping this cycle.',
cfg['retries'],
)
continue
if not t or not h:
logging.warning('Sensor returned empty reading; retrying.')
if num + 1 < cfg['retries']:
time.sleep(cfg['timeout'])
continue
logging.debug('Temperature and humidity read as %s and %s', t, h)
if common.reading_is_plausible(t, h, oldtemp, oldhumid, limits):
updateMysql.main(
t, h,
cfg['host'], cfg['db'], cfg['username'], cfg['password'],
logging, cfg['sql_retries'], cfg['sql_timeout'],
)
oldtemp = t
oldhumid = h
break
else:
logging.error('Temperature {0} or humidity {1} is outside of allowable values - error! Check your configuration.'.format(t, h))
else:
logging.warning('Failed to read from sensor, maybe try again?')
endTime=datetime.now()
logging.debug('This round of results ended at {0}'.format(endTime))
duration = endTime - startTime
logging.debug('This round of results took {0} to complete'.format(duration))
if num + 1 < cfg['retries']:
time.sleep(cfg['timeout'])
duration = time.time() - start
logging.debug('Sensor read cycle took %.2f seconds', duration)
return duration
DHT11 = 11
DHT22 = 22
AM2302 = 22
config = ConfigParser.ConfigParser()
config.read('/etc/thMonitor.conf')
hwtype=config.get('hardware', 'DHT')
pin=config.get('hardware', 'PIN')
retries=int(config.get('software', 'retries'))
timeout=int(config.get('software', 'timeout'))
interval=int(config.get('software', 'interval'))
maxtemp=int(config.get('software', 'maxtemp'))
mintemp=int(config.get('software', 'mintemp'))
tempdiff=int(config.get('software', 'tempdiff'))
maxhumid=int(config.get('software', 'maxhumid'))
minhumid=int(config.get('software', 'minhumid'))
humiddiff=int(config.get('software', 'humiddiff'))
logfile=(config.get('software', 'logfile'))
loglevel=(config.get('software', 'loglevel'))
host=(config.get('database', 'host'))
db=(config.get('database', 'db'))
username=(config.get('database', 'username'))
password=(config.get('database', 'password'))
sql_retries=int((config.get('database', 'sql_retries')))
sql_timeout=(config.get('database', 'sql_timeout'))
def run_loop(cfg, dev_type, dhtpin):
"""Run sensor reads on a fixed interval, accounting for read duration."""
interval = cfg['interval']
logging.debug('Reading sensor every %d seconds', interval)
while True:
start = time.time()
sensor_read(cfg, dev_type, dhtpin)
elapsed = time.time() - start
sleep_for = max(0, interval - elapsed)
logging.debug('Sleeping %.2f seconds until next reading', sleep_for)
time.sleep(sleep_for)
if loglevel == "debug":
logging.basicConfig(filename = logfile, format='%(asctime)s %(levelname)s:%(message)s', datefmt='%Y-%m-%d %H:%M:%S', level=logging.DEBUG)
elif loglevel == "info":
logging.basicConfig(filename = logfile, format='%(asctime)s %(levelname)s:%(message)s', datefmt='%Y-%m-%d %H:%M:%S', level=logging.INFO)
elif loglevel == "warn":
logging.basicConfig(filename = logfile, format='%(asctime)s %(levelname)s:%(message)s', datefmt='%Y-%m-%d %H:%M:%S', level=logging.WARNING)
elif loglevel == "error":
logging.basicConfig(filename = logfile, format='%(asctime)s %(levelname)s:%(message)s', datefmt='%Y-%m-%d %H:%M:%S', level=logging.ERROR)
else:
logging.basicConfig(filename = logfile, format='%(asctime)s %(levelname)s:%(message)s', datefmt='%Y-%m-%d %H:%M:%S', level=logging.CRITICAL)
def main():
cfg = common.load_config()
common.setup_logging(cfg['logfile'], cfg['loglevel'])
dhtreader.init()
dev_type = common.resolve_dht_type(cfg['hwtype'])
dhtpin = common.validate_pin(cfg['pin'])
dev_type = None
if hwtype == "11":
dev_type = DHT11
logging.info('Configured to use DHT11 device')
elif hwtype == "22":
dev_type = DHT22
logging.info('Configured to use DHT22 device')
elif hwtype == "2302":
dev_type = AM2302
logging.info('Configured to use AM2303 device')
else:
logging.warn('Invalid hardware type, only DHT11, DHT22 and AM 2302 are supported for now.!')
sys.exit(3)
logging.info(
'Multiple (infinite loop) temperature and humidity reading '
'[version: 1.1, Jonathan Ervine, 2015-06-17]'
)
run_loop(cfg, dev_type, dhtpin)
dhtpin = int(pin)
if dhtpin <= 0:
logging.warn("Invalid GPIO pin#, correct your configuration file")
sys.exit(3)
logging.info("using pin #{0}".format(dhtpin))
logging.info('Multiple (infinte looped) run temperature and humidity reading. [version: 1.0, Jonathan Ervine, 2015-06-17]')
logging.debug("About to enter infinite loop")
exec_every_n_seconds(60,sensorRead,hwtype,pin,retries,timeout,maxtemp,mintemp,tempdiff,maxhumid,minhumid,humiddiff)
if __name__ == '__main__':
main()
+65 -90
View File
@@ -1,111 +1,86 @@
#!/usr/bin/env python
# -*- coding:utf-8 -*-
import sys
import logging
import time
import dhtreader
import updateMysql
import readMysql
import ConfigParser
import logging
import time
from time import strftime
from datetime import datetime
from datetime import timedelta
import thmonitor_common as common
oldtemp = "NULL"
oldhumid = "NULL"
def sensorRead(hwtype, pin, retries, timeout, maxtemp, mintemp, tempdiff, maxhumid, minhumid, humiddiff):
global oldtemp
global oldhumid
oldtemp, oldhumid = readMysql.main(host, db, username, password, logging, sql_retries, sql_timeout)
logging.debug('We have returned the following previous temperature {0} and humidity {1} values.'.format(oldtemp, oldhumid))
for num in range(retries):
def sensor_read(cfg, dev_type, dhtpin):
"""Perform a single sensor read using the last DB values for validation."""
oldtemp, oldhumid = readMysql.main(
cfg['host'], cfg['db'], cfg['username'], cfg['password'],
logging, cfg['sql_retries'], cfg['sql_timeout'],
)
logging.debug(
'Previous temperature %s and humidity %s loaded from database.',
oldtemp, oldhumid,
)
limits = {
'maxtemp': cfg['maxtemp'],
'mintemp': cfg['mintemp'],
'tempdiff': cfg['tempdiff'],
'maxhumid': cfg['maxhumid'],
'minhumid': cfg['minhumid'],
'humiddiff': cfg['humiddiff'],
}
for num in range(cfg['retries']):
try:
t, h = dhtreader.read(dev_type, dhtpin)
except:
if ((num + 1) < retries):
logging.warning('Exception detected! We will retry. Loop number: %d', num)
time.sleep(timeout)
except Exception:
if num + 1 < cfg['retries']:
logging.warning(
'Exception during sensor read; retry %d/%d',
num + 1, cfg['retries'],
)
time.sleep(cfg['timeout'])
else:
logging.error('Exception detected - we are out of retries. Skipping the measurement in this cycle.')
else:
if t and h:
logging.debug('The temperature and humidity have been read as {0} and {1}'.format(t, h))
if (oldtemp != "NULL") and ((t - oldtemp < tempdiff) or (oldtemp - t < tempdiff)) and ((h - oldhumid < humiddiff) or (oldhumid - h < humiddiff)):
logging.debug('Current temperature close enough to previous temperature and previous temperature is not NULL, it is: %s', oldtemp)
logging.debug('Current humidity close enough to previous humidity and previous humidity is not NULL, it is: %s', oldhumid)
if (t < maxtemp) and (t > mintemp) and (h < maxhumid) and (h > minhumid):
logging.debug('Temperature is less than {0} and greater than {1}, humidity is less than {2} and greater than {3}'.format(maxtemp,mintemp,maxhumid,minhumid))
updateMysql.main(t, h, host, db, username, password, logging, sql_retries, sql_timeout)
oldtemp=t
oldhumid=h
break
else:
logging.error('Temperature {0} or humidity {1} is outside of allowable values - error! Check your configuration.'.format(t, h))
else:
logging.warning('Failed to read from sensor, maybe try again?')
logging.error(
'Sensor read failed after %d attempts; giving up.',
cfg['retries'],
)
continue
if not t or not h:
logging.warning('Sensor returned empty reading; retrying.')
if num + 1 < cfg['retries']:
time.sleep(cfg['timeout'])
continue
logging.debug('Temperature and humidity read as %s and %s', t, h)
if common.reading_is_plausible(t, h, oldtemp, oldhumid, limits):
updateMysql.main(
t, h,
cfg['host'], cfg['db'], cfg['username'], cfg['password'],
logging, cfg['sql_retries'], cfg['sql_timeout'],
)
return 0
DHT11 = 11
DHT22 = 22
AM2302 = 22
if num + 1 < cfg['retries']:
time.sleep(cfg['timeout'])
config = ConfigParser.ConfigParser()
config.read('/etc/thMonitor.conf')
hwtype=config.get('hardware', 'DHT')
pin=config.get('hardware', 'PIN')
retries=int(config.get('software', 'retries'))
timeout=int(config.get('software', 'timeout'))
interval=int(config.get('software', 'interval'))
maxtemp=int(config.get('software', 'maxtemp'))
mintemp=int(config.get('software', 'mintemp'))
tempdiff=int(config.get('software', 'tempdiff'))
maxhumid=int(config.get('software', 'maxhumid'))
minhumid=int(config.get('software', 'minhumid'))
humiddiff=int(config.get('software', 'humiddiff'))
logfile=(config.get('software', 'logfile'))
loglevel=(config.get('software', 'loglevel'))
host=(config.get('database', 'host'))
db=(config.get('database', 'db'))
username=(config.get('database', 'username'))
password=(config.get('database', 'password'))
sql_retries=int((config.get('database', 'sql_retries')))
sql_timeout=(config.get('database', 'sql_timeout'))
return 1
if loglevel == "debug":
logging.basicConfig(filename = logfile, format='%(asctime)s %(levelname)s:%(message)s', datefmt='%Y-%m-%d %H:%M:%S', level=logging.DEBUG)
elif loglevel == "info":
logging.basicConfig(filename = logfile, format='%(asctime)s %(levelname)s:%(message)s', datefmt='%Y-%m-%d %H:%M:%S', level=logging.INFO)
elif loglevel == "warn":
logging.basicConfig(filename = logfile, format='%(asctime)s %(levelname)s:%(message)s', datefmt='%Y-%m-%d %H:%M:%S', level=logging.WARNING)
elif loglevel == "error":
logging.basicConfig(filename = logfile, format='%(asctime)s %(levelname)s:%(message)s', datefmt='%Y-%m-%d %H:%M:%S', level=logging.ERROR)
else:
logging.basicConfig(filename = logfile, format='%(asctime)s %(levelname)s:%(message)s', datefmt='%Y-%m-%d %H:%M:%S', level=logging.CRITICAL)
def main():
cfg = common.load_config()
common.setup_logging(cfg['logfile'], cfg['loglevel'])
dhtreader.init()
dev_type = common.resolve_dht_type(cfg['hwtype'])
dhtpin = common.validate_pin(cfg['pin'])
dev_type = None
if hwtype == "11":
dev_type = DHT11
logging.info('Configured to use DHT11 device')
elif hwtype == "22":
dev_type = DHT22
logging.info('Configured to use DHT22 device')
elif hwtype == "2302":
dev_type = AM2302
logging.info('Configured to use AM2303 device')
else:
logging.warn('Invalid hardware type, only DHT11, DHT22 and AM 2302 are supported for now.!')
sys.exit(3)
logging.info(
'Single run temperature and humidity reading '
'[version: 1.1, Jonathan Ervine, 2015-06-17]'
)
return sensor_read(cfg, dev_type, dhtpin)
dhtpin = int(pin)
if dhtpin <= 0:
logging.warn("Invalid GPIO pin#, correct your configuration file")
sys.exit(3)
logging.info("using pin #{0}".format(dhtpin))
logging.info('Single run temperature and humidity reading. [version: 1.0, Jonathan Ervine, 2015-06-17]')
sensorRead(hwtype,pin,retries,timeout,maxtemp,mintemp,tempdiff,maxhumid,minhumid,humiddiff)
if __name__ == '__main__':
raise SystemExit(main())
+128
View File
@@ -0,0 +1,128 @@
#!/usr/bin/env python
# -*- coding: utf-8 -*-
"""Shared configuration, logging, and sensor validation for thMonitor scripts."""
from __future__ import print_function
import sys
import logging
import ConfigParser
DHT11 = 11
DHT22 = 22
AM2302 = 22
DEFAULT_CONFIG = '/etc/thMonitor.conf'
def load_config(path=DEFAULT_CONFIG):
"""Load and return thMonitor configuration as a dict."""
config = ConfigParser.ConfigParser()
if not config.read(path):
print('ERROR: configuration file not found: {0}'.format(path), file=sys.stderr)
sys.exit(1)
return {
'config_path': path,
'hwtype': config.get('hardware', 'DHT'),
'pin': config.get('hardware', 'PIN'),
'retries': config.getint('software', 'retries'),
'timeout': config.getint('software', 'timeout'),
'interval': config.getint('software', 'interval'),
'maxtemp': config.getint('software', 'maxtemp'),
'mintemp': config.getint('software', 'mintemp'),
'tempdiff': config.getint('software', 'tempdiff'),
'maxhumid': config.getint('software', 'maxhumid'),
'minhumid': config.getint('software', 'minhumid'),
'humiddiff': config.getint('software', 'humiddiff'),
'logfile': config.get('software', 'logfile'),
'loglevel': config.get('software', 'loglevel'),
'host': config.get('database', 'host'),
'db': config.get('database', 'db'),
'username': config.get('database', 'username'),
'password': config.get('database', 'password'),
'sql_retries': config.getint('database', 'sql_retries'),
'sql_timeout': config.getint('database', 'sql_timeout'),
}
def setup_logging(logfile, loglevel):
"""Configure logging from config file settings."""
levels = {
'debug': logging.DEBUG,
'info': logging.INFO,
'warn': logging.WARNING,
'error': logging.ERROR,
'critical': logging.CRITICAL,
}
level = levels.get(loglevel.lower(), logging.CRITICAL)
logging.basicConfig(
filename=logfile,
format='%(asctime)s %(levelname)s:%(message)s',
datefmt='%Y-%m-%d %H:%M:%S',
level=level,
)
def resolve_dht_type(hwtype):
"""Map config hardware type string to dhtreader device constant."""
types = {
'11': (DHT11, 'DHT11'),
'22': (DHT22, 'DHT22'),
'2302': (AM2302, 'AM2302'),
}
if hwtype not in types:
logging.warn(
'Invalid hardware type %r; supported values are 11, 22, and 2302',
hwtype,
)
sys.exit(3)
dev_type, name = types[hwtype]
logging.info('Configured to use %s device', name)
return dev_type
def validate_pin(pin):
"""Return GPIO pin number or exit if invalid."""
dhtpin = int(pin)
if dhtpin <= 0:
logging.warn('Invalid GPIO pin number: %s', pin)
sys.exit(3)
logging.info('using pin #%d', dhtpin)
return dhtpin
def reading_is_plausible(t, h, oldtemp, oldhumid, limits):
"""
Return True if reading is within configured bounds and not an abrupt jump
from the previous values.
"""
if not (limits['mintemp'] < t < limits['maxtemp']):
logging.error(
'Temperature %s outside allowable range (%d, %d)',
t, limits['mintemp'], limits['maxtemp'],
)
return False
if not (limits['minhumid'] < h < limits['maxhumid']):
logging.error(
'Humidity %s outside allowable range (%d, %d)',
h, limits['minhumid'], limits['maxhumid'],
)
return False
if oldtemp != 'NULL' and abs(t - oldtemp) >= limits['tempdiff']:
logging.warning(
'Temperature jump too large: current=%s previous=%s (limit=%d)',
t, oldtemp, limits['tempdiff'],
)
return False
if oldhumid != 'NULL' and abs(h - oldhumid) >= limits['humiddiff']:
logging.warning(
'Humidity jump too large: current=%s previous=%s (limit=%d)',
h, oldhumid, limits['humiddiff'],
)
return False
return True
+33 -19
View File
@@ -2,33 +2,47 @@
##
## Script to import the temperature and humidity into a MySQL database
##
import sys
import time
import MySQLdb
def main(temp, humid, host, db, user, passwd, logging, sql_retries, sql_timeout):
logging.debug('Temp = {0} *C, Hum = {1} %'.format(temp, humid))
logging.debug('Temp = %s *C, Hum = %s %%', temp, humid)
logging.debug('Updating MySQL database next ...')
sql = (
'INSERT INTO TempHumid (ComputerTime, Temperature, Humidity, id) '
'VALUES (unix_timestamp(now()), %s, %s, NULL)'
)
args = (format(temp, '5.1f'), format(humid, '5.1f'))
logging.info(
'Temperature: %s*C Humidity: %s%% ... updating to MySQL database',
args[0], args[1],
)
for attempt in range(sql_retries):
connection = None
try:
connection = MySQLdb.connect(host, user, passwd, db)
cursor = connection.cursor()
sqltemp=format(temp, '5.1f')
sqlhumid=format(humid, '5.1f')
logging.info('Temperature: {0}*C Humidity: {1}% ... updating to MySQL database'.format(sqltemp, sqlhumid))
sql = """INSERT INTO TempHumid (ComputerTime, Temperature, Humidity, id) VALUES (unix_timestamp(now()), %s, %s, NULL)"""
args = (sqltemp, sqlhumid)
success = False
attempts = 0
while attempts < sql_retries and not success:
try:
cursor.execute(sql, args)
connection.commit()
cursor.close()
success = True
logging.debug('The MySQL database was successfully updated.')
except MySQLdb.Error, e:
logging.warn('The MySQL database could not be updated and returned the following error %d: %s', (e.args[0], e.args[1]))
attempts += 1
if attempts == sql_retries:
logging.error('All configured attempts to update the MySQL database have failed. We are going to skip this attempt.')
time.sleep(sql_interval)
return 0
except MySQLdb.Error as e:
logging.warn(
'MySQL update failed (attempt %d/%d): %d: %s',
attempt + 1, sql_retries, e.args[0], e.args[1],
)
if attempt + 1 >= sql_retries:
logging.error(
'All configured attempts to update the MySQL database have failed.'
)
return 1
time.sleep(sql_timeout)
finally:
if connection is not None:
connection.close()
return 1
-1
View File
@@ -49,7 +49,6 @@
</script>
<script type="text/javascript" src="jQuery.js"></script>
<script type="text/javascript">
$(document).ready(function(){