Files
rpi-temp-humid-monitor/python_code/temp-humid-read-loop.py
T

103 lines
2.9 KiB
Python
Executable File

#!/usr/bin/env python3
# -*- coding: utf-8 -*-
import logging
import time
import dhtreader
import updateMysql
import thmonitor_common as common
oldtemp = 'NULL'
oldhumid = 'NULL'
def sensor_read(cfg, dev_type, dhtpin):
"""Read sensor, validate, and store a single measurement."""
global oldtemp, oldhumid
start = time.time()
limits = {
'maxtemp': cfg['maxtemp'],
'mintemp': cfg['mintemp'],
'tempdiff': cfg['tempdiff'],
'maxhumid': cfg['maxhumid'],
'minhumid': cfg['minhumid'],
'humiddiff': cfg['humiddiff'],
}
for num in range(cfg['retries']):
try:
t, h = dhtreader.read(dev_type, dhtpin)
except Exception:
if num + 1 < cfg['retries']:
logging.warning(
'Exception during sensor read; retry %d/%d',
num + 1, cfg['retries'],
)
time.sleep(cfg['timeout'])
else:
logging.error(
'Sensor read failed after %d attempts; skipping this cycle.',
cfg['retries'],
)
continue
if not t or not h:
logging.warning('Sensor returned empty reading; retrying.')
if num + 1 < cfg['retries']:
time.sleep(cfg['timeout'])
continue
logging.debug('Temperature and humidity read as %s and %s', t, h)
if common.reading_is_plausible(t, h, oldtemp, oldhumid, limits):
updateMysql.main(
t, h,
cfg['host'], cfg['db'], cfg['table'],
cfg['username'], cfg['password'],
logging, cfg['sql_retries'], cfg['sql_timeout'],
)
oldtemp = t
oldhumid = h
break
if num + 1 < cfg['retries']:
time.sleep(cfg['timeout'])
duration = time.time() - start
logging.debug('Sensor read cycle took %.2f seconds', duration)
return duration
def run_loop(cfg, dev_type, dhtpin):
"""Run sensor reads on a fixed interval, accounting for read duration."""
interval = cfg['interval']
logging.debug('Reading sensor every %d seconds', interval)
while True:
start = time.time()
sensor_read(cfg, dev_type, dhtpin)
elapsed = time.time() - start
sleep_for = max(0, interval - elapsed)
logging.debug('Sleeping %.2f seconds until next reading', sleep_for)
time.sleep(sleep_for)
def main():
cfg = common.load_config()
common.setup_logging(cfg['logfile'], cfg['loglevel'])
dhtreader.init()
dev_type = common.resolve_dht_type(cfg['hwtype'])
dhtpin = common.validate_pin(cfg['pin'])
logging.info(
'Multiple (infinite loop) temperature and humidity reading '
'[version: 2.0, Python 3]'
)
run_loop(cfg, dev_type, dhtpin)
if __name__ == '__main__':
main()